Meperidine, Urine
Meperidine is a synthetic opioid agonist. Meperidine is less potent than morphine and has a shorter duration of action. The typical route of administration is by injection. Oral formulations are available but are not recommended for long-term use. The major metabolite of meperidine is normeperidine, which is a stimulant and is associated with seizures and neurotoxicity when it accumulates. Evaluation of normeperidine accumulation and toxicity is best accomplished with blood testing rather than urine testing. The half-life of meperidine is 2-5 hours.
Elimination is promoted under conditions of acid urine, and inhibited under conditions of alkaline urine. Actual elimination depends on factors such as drug formulation, dose, dose frequency, clinical status and pharmacokinetics of the individual patient.
Common side effects: respiratory depression, sedation, nausea, vomiting, dizziness, miosis, constipation, urinary retention. Meperidine can also contribute to the following effects: serotonin syndrome, seizures, euphoria, sedation, mental clouding, amnesia, hostility, irritability, pruritis, and vivid or disturbing dreams. Can be addictive. Overdose effects include respiratory collapse, seizure, coma, and possible death.
Meperidine can be analyzed in urine by a variety of analytical methods (see below); both qualitative and quantitative tests are available.
- Adherence monitoring
- Drug abuse evaluation
- Toxicity/Overdose assessment
Therapeutic Level: 10-100 ng/ml
Toxic level: >200 ng/ml
Note: therapeutic ranges and toxic thresholds are best evaluated from blood samples. Quantitative results obtained with blood samples collected at specific times after drug administration are preferred for pharmacokinetic analyses.
Cut-Off Ranges
Cut-off values are used to determine the positivity of the urine specimen being analyzed. Cut-off values can vary based on the particular method of analysis that is used for detection, or laboratory, whether the test is a qualitative method or a quantitative method. The testing laboratory cut-off range is listed on the patient report.
Fresh urine specimen (random) collected in either a clean glass or plastic container. An acceptable urine specimen submitted for testing should be in the pH range of 3-11. Creatinine or specific gravity results will identify dilute specimens. Adulteration of the urine specimen can result in erroneous results.
Stability
- Ambient: 3-5 days
- Refrigeration: 7-14 days
- Frozen: 30 days
- Baselt RC (ed). Disposition of toxic drugs and chemicals in man, 9th ed. Forster City, CA: Biomedical Publications; 2011.
- Brunton LL, Chabner B, Knollman B (eds). Goodman and Gilmans’ the pharmacological basis of therapeutics, 12th ed. New York: McGraw-Hill; 2010.
- Katzung BG, Masters S, Trevor AK (eds). Basic and clinical pharmacology, 12th ed. New York: McGraw-Hill; 2011.