Lysergic Acid Diethylamide, Urine
Lysergic acid diethylamide (LSD) is a semisynthetic psychedelic drug of abuse known for its strong hallucinogenic properties. It was originally introduced as a psychiatric medication (Delysid), and was considered in the 1950s for use in military-facilitated "mind control." The d-isomer is one of the most potent hallucinogenic agents known. Visual changes and mood alterations precede hallucinatory symptoms that include distorted perception of the size, shape, color, position and movement of the objects and disorientation to time, place and person. The typical route of administration is oral. The half-life of LSD is 3-4 hours. Only <1% being excreted in the urine in unchanged form, which remains detectable for a very short period of time (10-12 hours after ingestion). However, 2-oxo-3-hydroxy LSD (O-H-LSD), a metabolite of LSD, has a longer half-life and hence is a reliable surrogate marker of LSD abuse.
The concentration of O-H-LSD is significantly higher than LSD (up to 43 times that of the parent drug). *Iso*-LSD is an isomer of LSD and is formed during the illicit synthesis of LSD from lysergic acid. LSD can be detected in urine by a variety of analytical methods (see below); both qualitative and quantitative tests are available.
- Drug abuse evaluation
- Toxicity/Overdose assessment
Negative
Note: therapeutic ranges and toxic thresholds are best evaluated from blood samples. Quantitative results obtained with blood samples collected at specific times after drug administration is preferred for pharmacokinetic analyses.
Cut-Off Ranges
Cut-off values are used to determine the positivity of the urine specimen being analyzed. Cut-off values can vary based on the particular method of analysis that is used for detection or laboratory, or whether the test is a qualitative method or a quantitative method. Detection will be improved with low cutoff concentrations. The testing laboratory cut-off range is listed on the patient report.
Fresh urine specimen (random) collected in either a clean glass or plastic container. An acceptable urine specimen submitted for testing should be in the pH range of 3-11. Creatinine or specific gravity results will identify dilute specimens. Adulteration of the urine specimen can result in erroneous results. Specimens should be Protect from light.
Stability
- Ambient 5 days
- Refrigeration 7 days
- Frozen 30 days
- Clin Chem. 1998 Feb;44(2):287-92 [PMID: 9474026]
- J Anal Toxicol. 2009 Jun;33(5):253-9 [PMID: 19671244]
- J Anal Toxicol. 2000 Apr;24(3):170-9 [PMID: 10774536]
- J Anal Toxicol. 1997 May-Jun;21(3):181-4 [PMID: 9171199]
- Baselt RC (ed). Disposition of toxic drugs and chemicals in man, 9th ed. Foster City, CA: Biomedical Publications; 2011.