LDS/Medical Tests/Dilute Russell Viper Venom Time (dRVVT)

Dilute Russell Viper Venom Time (dRVVT)

RVVT is used primarily in detection of antiphospholipid antibodies (so-called lupus anticoagulant, LAC). It should be noted that this anticoagulant, detected in vitro, may be associated with vascular thrombosis and pregnancy-related morbidity in vivo. The test is sensitive to phospholipid, and if heparin is not present, a prolonged RVVT may indicate the presence of LAC (antiphospholipid antibodies). A prolonged RVVT using patient plasma is suspicious for LAC, but this must be confirmed by a mixing study utilizing patient and normal sera.  If the time does not correct using normal and patient plasma but does correct upon substituting platelets for phospholipid, this is confirmation of a LAC.  Lupus anticoagulant antibodies are IgG or IgM or both, directed against phospholipids including those added as part of the aPTT test.  Only about 20% of LACs occur in systemic lupus;  other conditions in which LACs may be seen include other autoimmune diseases, malignancies, infections, AIDS, certain drugs (chlorpromazine, procainamide, thorazine) children with tonsillitis and adenoiditis and in otherwise normal persons.  See “Isolated Prolongation of PTT: Laboratory Evaluation” for its use in evaluating isolated prolongation of PTT.

Factor deficiency can be differentiated from LAC in one of two ways.  The patient sample can be mixed 1:1 with pooled normal plasma and if the ratio of the mixture RVVT to pooled normal plasma RVVT is within reference range, it is negative for LAC and a specific factor deficiency must be sought.  Alternately, excess phospholipid can be added to patient plasma and the ratio of patient sample RVTT to the mixture RVVT is calculated and if within reference range, LAC is excluded and a factor deficiency should be sought.

Russelll vipe venom is extracted from a pit viper (Vipera russelli), which is common in Southeast Asia (especially Burma), and causes a rapidly fatal syndrome of consumptive coagulopathy with hemorrhage, shock, rhabdomyolysis, and renal failure.  Approximately 70% of the protein content of the venom is phospholipase A2 (a serine esterase), which activates factor X in the presence of phospholipid, bypassing Factor VII.  This test is also useful for patients that exhibit a prolonged PT with a normal aPTT and Thrombin time.  In this clinical setting a normal RVVT would suggest a deficiency of Factor VII.  Clinical bleeding does not occur with LAC because platelet membranes provide phospholipids for coagulation complexes to form, which are not inhibited by LAC.

  • Diagnostically useful for the detection of antiphospholipid antibodies
  • Useful in the detection of Factor VII deficiency

Increased in:

  • Circulating lupus anticoagulant (anti-phospholipid antibody)
  • Severe fibrinogen deficiency
  • Deficiencies in Prothrombin, Factor V, Factor X
  • Heparin therapy

Normal in:

  • Factor VII deficiency and all intrinsic pathway factor deficiencies

24–37 seconds
 

 

 

Optical or Mechanical Clot Detection

Plasma Citrate (Light Blue).

Stability

  • Ambient: 4 hr
  • Refrigerated: Unacceptable
  • Frozen: 14 days
  • Place on ice and separate plateletpoor plasma by centrifugation at 4°C.
  • Freeze immediately and maintain frozen until tested.
Prothrombin Time, Activated Partial Thromboplastin Time, Thrombin Time, Specific Factor level assay, Anti-Cardiolipin IgM, IgG, and IgA antibodies, Anti-Β2 glycoprotein 1 antibody.
1-3 days.
Please log in to view content.
Create an account to get a 30-day free trial.
Login
Please log in to view content.
Create an account to get a 30-day free trial.
Login
Please log in to view content.
Create an account to get a 30-day free trial.
Login
  • Am J Clin Pathol. 2005;124:894. [PMID: 16416739]
  • Br J Biomed Sci. 2005;62:127. [PMID: 16196459]
  • Semin Thromb Hemost. 2005;31:39. [PMID: 15706474]
  • Henry JB. Clinical Diagnosis and Management by Laboratory Methods. 19th. Philadelphia. W.B. Saunders Company (1996).
  • Jacobs DS and DeMott WR. Laboratory Test Handbook. 5th. Hudson, OH. Lexi-Comp, Inc (2001).