D-Xylose Absorption Test
D-Xylose absorption testing is a simple, low-cost method of screening for small intestinal carbohydrate malabsorption. D-xylose is a pentose found naturally in plants. Its incomplete absorption allows it to be used as an absorptive test. It is absorbed unchanged from the small intestine, and approximately 30% is metabolized by the liver to carbon dioxide (CO2) and threitol. In addition, 5% of the absorbed dose is excreted unchanged in the bile and undergoes enterohepatic cycling. The remainder is excreted in the urine, allowing for its use in clinical testing. The standard 25g D-Xylose test in adults, based on analysis of 5-hours urine collection and a 1-hour serum sample, discriminates between normal subjects and patients with proximal small intestinal malabsorption with greater than 95% specificity and sensitivity. Also, the 1-hour serum level measured after administering this dose might be useful in evaluating malabsorption in patients with intermediate degrees of renal insufficiency and in the elderly. The 1-hour serum test after administration of 5g of D-Xylose should be used in pediatrics and is greater than 91% sensitive and close to 100% specific. The 14CD-Xylose breath test using 1g of D-Xylose has been useful in identifying malabsorption caused by bacterial overgrowth in the small intestine.
This test can also be helpful in distinguishing intestinal malabsorption (decreased D absorption) from pancreatic insufficiency but with the normal intestinal D-Xylose absorption.
- To evaluate the functional integrity of the jejunum in possible malabsorption
- As an aid to diagnosis and to distinguish mucosal disease from the malabsorption of chronic pancreatic disease
- As an aid in the diagnosis of celiac disease and other common small bowel disorders
- As an aid in the diagnosis of Crohn’s disease
Decreased in:
- Primary intestinal malabsorption
- Mucosal disease such as celiac disease
- Small intestinal bacterial overgrowth
- Renal insufficiency
- Small intestinal HIV enteropathy
- Cryptosporidiosis
- Cytotoxic therapy-related malabsorption
- Also decreased in amyloidosis and other collagen deposition diseases
- Some lymphomas
>5 g per 5-hour urine (>20% excreted in 5 hours)
1-Hour Serum > 25 mg/dL
Both the 5-hour urine test and the 1-hour serum test have an approximate sensitivity and specificity of 95% when used to discriminate between patients with proximal malabsorption and normal patients or patients with pancreatic insufficiency.
Patients should be well hydrated and fast for 6 hours prior to the test. After giving 25 grams of D-Xylose orally (children less than 12 years old are given 5 grams), urine is collected for exactly five hours.
One SST tube of blood is drawn exactly one hour after xylose administration.
Stability
- Ambient: 1-3 days
- Refrigerated: 3-5 days
- Scand J Gastroenterol. 2010 Nov;45(11):1289-94. [PMID: 20626306]
- Gastroenterology. 1988 Jul;95(1):223-31. [PMID: 3286361]
- J Clin Gastroenterol. 1999 Sep;29(2):143-50. [PMID: 10478874]
- J Clin Gastroenterol. 2001;33:36. [PMID: 11418788]
- Clin Gastroenterol Hepatol. 2005;3:679. [PMID: 16206501]
- Alan Wu. Tietz Clinical Guide to Laboratory Tests, Fourth Edition. Saunders; 4 edition (June 13, 2006). ISBN-10: 0721679757